Compatibility
This locomotive is capable of operating on
AC or DC output power supplies (See page
25 for a complete list of compatible
transformers and wiring instructions.) and
indoors or outdoors. MTH does not
recommend operating the locomotive in
inclement weather and strongly suggests that
it not be left out in the elements. The
locomotive will negotiate an R2 G-Gauge
curve track or switch. Additional features
may be utilized when controlling the engine
with MTH’s Digital Command System
(DCS).
PLEASE READ BEFORE USE AND SAVE
4-6-4 J3a Hudson Steam
Locomotive
OPERATOR’S MANUAL
Page view 0
1 2 3 4 5 6 ... 29 30

Summary of Contents

Page 1 - Locomotive

CompatibilityThis locomotive is capable of operating onAC or DC output power supplies (See page25 for a complete list of compatibletransformers and wi

Page 2 - Table of Contents

10 4-6-4 J3a Hudson Steam Locomotive The following pages contain the operating instructions for Proto-Sound 2.0 RailKingOne-Gauge locomoti

Page 3 - Set Up Checklist

11 4-6-4 J3a Hudson Steam LocomotiveYour engine is equipped with a sound package of freight yard sounds that you can playwhen you pull into

Page 4 - (cont’d)

12 4-6-4 J3a Hudson Steam Locomotive Tips on Using FYS• You can terminate FYS at any time by turning off power to the track for 15seconds.

Page 5 - Priming The Smoke Unit

4-6-4 J3a Hudson Steam Locomotive 13 M.T.H. engines equipped with Proto-Sound 2.0 have speed control capabilities that allow the engine to maintain

Page 6 - Checking The Battery

14 4-6-4 J3a Hudson Steam Locomotive You can lock your engine into a direction (forward, neutral, or reverse) so that it will notchange di

Page 7 - Basic Operation

4-6-4 J3a Hudson Steam Locomotive 15 MaintenanceThe engine should be well oiled and greased in order to run properly.You should regularly lubricate

Page 8 - Cycle Phases

16 4-6-4 J3a Hudson Steam Locomotive 2. After removing the boiler mounting screws, separate theboiler from the chassis and turn the chassi

Page 9

4-6-4 J3a Hudson Steam Locomotive 17 6. Lift the gearbox up and outof the chassis, rotate 190degrees to reveal the nowexposed gears and lubricatewi

Page 10 - Operating Instructions

18 4-6-4 J3a Hudson Steam Locomotive The locomotive and tender lights are controlled by a constant voltage circuit in theengine. They can

Page 11 - Freight Yard Sounds (FYS)

4-6-4 J3a Hudson Steam Locomotive 19 The special NiCad AA self-charging batteries recharge continuously during trainoperation and should last betwe

Page 12

CAUTION: ELECTRICALLY OPERATED PRODUCT:Not recommended for children under 10 years of age. M.T.H. recommends adult supervision with children ages 10

Page 13 - Speed Control

20 4-6-4 J3a Hudson Steam Locomotive This RailKing One-Gauge steam locomotive contains a self-powered smoke unit thatoutputs smoke through

Page 14 - Automatic Sound Effects

4-6-4 J3a Hudson Steam Locomotive 21 If you experience poor or no smoke output when the smoke unit is on and has fluid,check the wick to see if it h

Page 15 - Maintenance

22 4-6-4 J3a Hudson Steam Locomotive Although Proto-Sound 2.0 has been designed and engineered for ease of use, you mayhave some questions

Page 16 - (Under Leading Truck)

4-6-4 J3a Hudson Steam Locomotive 23 Cab ChatterLock-outVolumeBatteryFYSRemedyRemedyRemedyRemedyRemedySometimes the Cab Chatter sounds don’t play.I

Page 17 - Remove Gearbox Casing Screws

24 4-6-4 J3a Hudson Steam Locomotive FYS RemedyOnce in FYS, the engine doesn’t go into reverse.When the FYS enters its last sequence the b

Page 18 - Firebox Glow Connection

4-6-4 J3a Hudson Steam Locomotive 25 TransformerModelCenter Rail Outside RailMin/Max.VoltagePowerRatingTransformerTypeLionel 1032 U A 5-16v 90-Watt

Page 19 - Self Charging Battery Back-Up

26 4-6-4 J3a Hudson Steam Locomotive (Additional equipment required)While conventional mode operation of a Proto-Sound 2.0 engine yields w

Page 20 - ProtoSmoke® Unit Operation

How to Get Service Under the Terms of the Limited One-Year WarrantyFor warranty repair, follow the instructions below to obtain warranty service.First

Page 21 - Figure 24

28 4-6-4 J3a Hudson Steam Locomotive ALABAMAARIZONACALIFORNIACOLORADOCONNECTICUTDELAWAREFLORIDAILLINOISINDIANALOUISIANAMAINEMARYLANDMASSAC

Page 22

4-6-4 J3a Hudson Steam Locomotive 29 MISSOURINEW HAMPSHIRENEW JERSEYNEW YORKNORTH CAROLINAOHIOPENNSYLVANIASWITCH STANDSAINT LOUIS314-781-4458r41877@

Page 23

4-6-4 J3a Hudson Steam Locomotive 3 Set Up Checklist•Install the tender coupler• Lubricate the locomotive•Prime the smoke unit• Check to see whether

Page 24

30 4-6-4 J3a Hudson Steam Locomotive THE STATIONNEW [email protected] TRAINSAMBLER215-628-2366choochoos@

Page 25

Installing The Tender Coupler (cont’d)4 4-6-4 J3a Hudson Steam Locomotive If the locomotive is to be mated up with adifferent scaled G-Gau

Page 26 - Remote Control System

4-6-4 J3a Hudson Steam Locomotive 5 LubricationYou should lubricate the engine to prevent it from squeaking. Uselight household oil and follow the

Page 27 - Limited One-Year Warranty

6 4-6-4 J3a Hudson Steam Locomotive Checking The BatteryYou may find, if your locomotive was built several months before you set it up, th

Page 28 - AUTHORIZED SERVICE CENTER

4-6-4 J3a Hudson Steam Locomotive 7 Basic OperationRailKing One-Gauge locomotives can be operated with AC or DC power outputtransformers. When usi

Page 29

8 4-6-4 J3a Hudson Steam Locomotive Activating Features Using AC PowerUsing an AC output transformer equipped with a whistle and bell butt

Page 30

4-6-4 J3a Hudson Steam Locomotive 9 Manual Volume Adjustment - To adjust the volume of all sounds made by this engine,turn the master volume control

Comments to this Manuals