Rail King 0-4-0 Dockside Freight Set User Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
! Afterremovingtheenginefromstorage,addanother25dropsoffluid,lettingthe
wicksoakupthefluidfor15minutespriortooperation.
Ifyouexperiencepoorornosmokeoutputwhenthesmokeunitisonandhasfluid,
checkthewicktoseeifithasbecomehard,blackened,andunabsorbentaroundthe
heatingelement.Removetheboilerasshownonpage7.Removethesmokeunit
inspectioncoverfromthelocomotive's
body(seeright).Afterremovingthe
chassisandinspectioncoverscrews,lift
theinspectionplateawayandinspectthe
wick.Ifitisdarklydiscoloredandhard,it
shouldbereplaced.Whenprimingnew
wickadd40drops.
Toreplacethelightbulbinthelocomotive,followtheboiler
removalinstructionsonpage7.(Part#CA-0000051)
Oncethelocomotiveboilerhasbeenremovedfromitschassis,
locatethebulbbracketasseenintheillustrationontherightand
rotatetheheadlightbulbcounter-clockwisetoremove.
Toreplacetheinteriorlightbulbsfollowtheseinstructionsandseethediagramsbelow:
LocomotiveLightBulbReplacement
CabooseLightBulbReplacement
Removethefour(4)screwslocated
underthecaboose'strucks.
BayonetBulb
ReplaceaBayonetBulbbyturningandpullingup,
pullingthebulbfromitssocket.
SmokeUnitCover
Wickin
Poor
Condition
Wickin
Good
Condition
ReplaceHeadlightBulb
9
Lowerthechassis
fromtheshell,taking
carenottopullthe
wiresout.
(Part#CI-0000015)
1
2
RailKing0-4-0DocksideFreightSet
STEP STEP
STEP
Page view 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 19 20